Dirty Condenser Caused AC Compressor Overheating in Prairieville
An AC compressor in Prairieville was overheating, drawing approximately 30 amps, and shutting off on thermal overload. An inspection revealed a large ant mound and debris blocking part of the condenser coil. After cleaning, compressor amperage dropped to approximately 19–20 amps.An AC compressor in Prairieville was overheating, drawing approximately 30 amps, and shutting off on thermal overload. An inspection revealed a large ant mound and debris blocking part of the condense

Reggie Hebert
6 days ago4 min read


Downstairs Not Cooling in Prairieville? A Failed Zone Damper Was Blocking the Airflow
A Prairieville homeowner had little airflow downstairs even though the air conditioner was operating. We diagnosed a failed Zone 1 damper and found a crushed return ductboard plate pulling hot attic air into the system.

Reggie Hebert
Jul 294 min read


Why This Geismar Upstairs AC Was Not Keeping Up
An upstairs HVAC system in Geismar struggled with cooling, humidity, and weak airflow. We found closed registers, a closed duct damper, excessive discharge pressure, and a dirty condenser coil.

Reggie Hebert
Jul 295 min read


Why a Bard AC Kept Freezing at SA Recycling in Prairieville
A Bard wall-mounted air conditioner at SA Recycling in Prairieville kept freezing overnight even after an initial coil cleaning and blower-control repair. A deeper cleaning of the thick three-row evaporator coil uncovered heavy internal buildup, while refrigerant testing also revealed the system had been significantly overcharged. This Prairieville HVAC case study shows why airflow must be verified before adding refrigerant to a frozen air-conditioning system.

Reggie Hebert
Jul 295 min read


Why This Gonzales Heat Pump Was Heating Instead of Cooling
A previous diagnosis pointed to a bad capacitor, but complete testing uncovered two different problems: a disconnected reversing-valve plug and a refrigerant leak. Here is how the Gonzales heat pump was repaired without replacing a capacitor that was still testing properly.

Reggie Hebert
Jul 236 min read


Why This Denham Springs AC Had 30-Amp Fuses on Equipment Rated for Up to 55 Amps
A five-ton Denham Springs AC was still operating, but several electrical issues were making the system work harder than it should. Here’s what we found with the weak capacitor, aging hard-start kit, and 30-amp fuses on equipment rated for up to 55 amps.

Reggie Hebert
Jul 205 min read


Why Is My AC Running but Not Cooling—or Falling Behind in the Afternoon?
If your AC runs all afternoon but the indoor temperature keeps rising, learn the common causes, what you can check safely, and when to schedule HVAC service.

Reggie Hebert
Jul 196 min read