Dirty Condenser Caused AC Compressor Overheating in Prairieville

An AC compressor in Prairieville was overheating, drawing approximately 30 amps, and shutting off on thermal overload. An inspection revealed a large ant mound and debris blocking part of the condenser coil. After cleaning, compressor amperage dropped to approximately 19–20 amps.An AC compressor in Prairieville was overheating, drawing approximately 30 amps, and shutting off on thermal overload. An inspection revealed a large ant mound and debris blocking part of the condenser coil. After cleani

July 31, 2026 · HVAC Maintenance

AC Drain Overflow and Low Refrigerant in Pelican Point

A Pelican Point homeowner had water overflowing from an open condensate drain stack while the air conditioner was also low on R-410A refrigerant. We cleared the drain, corrected the overflow path, restored cooling, and prepared options for locating and repairing the refrigerant leak.

July 29, 2026 · HVAC Tips

Why This Geismar Upstairs AC Was Not Keeping Up

An upstairs HVAC system in Geismar struggled with cooling, humidity, and weak airflow. We found closed registers, a closed duct damper, excessive discharge pressure, and a dirty condenser coil.

July 29, 2026 · Duct Repair & Airflow

Why a Bard AC Kept Freezing at SA Recycling in Prairieville

A Bard wall-mounted air conditioner at SA Recycling in Prairieville kept freezing overnight even after an initial coil cleaning and blower-control repair. A deeper cleaning of the thick three-row evaporator coil uncovered heavy internal buildup, while refrigerant testing also revealed the system had been significantly overcharged. This Prairieville HVAC case study shows why airflow must be verified before adding refrigerant to a frozen air-conditioning system.

July 29, 2026 · AC Repair

Why This Gonzales Heat Pump Was Heating Instead of Cooling

A previous diagnosis pointed to a bad capacitor, but complete testing uncovered two different problems: a disconnected reversing-valve plug and a refrigerant leak. Here is how the Gonzales heat pump was repaired without replacing a capacitor that was still testing properly.